High Voltage Isolation Transformers
Introduction:
Due to the continuous Inhouse requirement of large Quantity of Isolation Transformers. We decided to manufacture these Transformers inhouse 6 years back and so far have never looked back. We have been manufacturing several type of Transformers with CRGO / CRNO Cores, Torroid Cores, E & I Cores and other associated Transformer hardwares. We specialize in Moulded Transformers with very High Voltage Insulation Systems.
Standard Transformers:
A range of standard Transformers are available with us. Standard Transformers upto 5KVA and a range of D.C. Isolation Voltage are available.
Type No | Pri V | Sec V | Power VA | Typical N/L to F/L Regulation | Range of Isolation Voltage in D.C | Leakage Current Pri to Sec | Leakage Current Sec to Core |
IT/220/300 | 220V | 220V | 300 | 8% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/500 | 220V | 220V | 500 | 8% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/1000 | 220V | 220V | 1000 | 8% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/1500 | 220V | 220V | 1500 | 8% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/2000 | 220V | 220V | 2000 | 8% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/3000 | 220V | 220V | 3000 | 10% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/4000 | 220V | 220V | 4000 | 10% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
IT/220/5000 | 220V | 220V | 5000 | 10% | 5KV TO 400KV | <50micro Amps | <50micro Amps |
Special Transformers are as follows:-
Primary :- 0 to 1000Volts (Voltage of your choice)
Secondary :- 0 to 2000Volts (Voltage of your choice)
Isolation :- 5KVDC to 400KVDC
Leakage Current : <= 50micro Amps at the maximum Working Voltage
Please contact us for Special Transformers as we derive great pleasure in designing New Transformers. All our Transformers are Vaccum moulded and processed under Vaccum. Maximum Transformers are used for Industrial as well as Research Purposes.
Kindly contact us for specific requirement
High Voltage Ignition System
High Voltage Ignition Systems are essentially used in applications like Gasturbine engine starting or burning of Lateral fuel in Gasturbines or application where, a burst of energy is required for certain experimentation the Unit consists of a High Voltage SMPS source which generates the D.C Voltage typically around 6KVDC, 10KVDC and 12KVDC. These models generate energy in the level of 10 to 25 Joules and the High Voltage produced by these units charges a Capacitor which is coupled to a suitable peaking Spark Gap and this Spark Gap gives a high Impedence, coupling the Load, so invariably of the load Impedence, the Spark Gap will transfer the energy to the load for a Load Impedence as Low as 1Mega Ohms at 12KVDC. Sufficient energy can be transferred to the Load without much effort from the Unit. These Units are moulded and very suitable for applications where the energy has to be transferred to dirty Loads which are normally submerged into dirty environments like Oil, grit, grease etc.
Type | Working Voltage | Energy | Capacitance | PRR | I/p Voltage | Packing |
ZE/IS/6 | 6KVDC | 36Joules | 6mfd | 2PPS | 24Volt D.C. | Moulded |
ZE/IS/10 | 10KVDC | 25Joules | 0.5mfd | 2PPS | 24Volt D.C. | Moulded |
ZE/IS/12 | 12KVDC | 36Joules | 0.5mfd | 1PPS | 24Volt D.C. | Moulded |
These Units are very Compact as well as reliable.
A Specialised 100 Joules Ignition System developed for fusion work. |